OWNER’S MANUAL
GP-SW050
Residential Duty Swing Gate Operator
With Inherent UPS Battery Back-up System
GPSW050 rev - 04/07/08
Printed in China for GTO, inc.
This product meets and exceeds the requirements of UL 325 gate operator safety standards.
For more information on GTO’s full line of automatic gate openers and access controls visit our website at www.gtoaccess.com
L
I
S
T
E
D
US
TWO 12VDC, U1, 230A BATTERIES ARE REQUIRED BUT NOT INCLUDED.
DO NOT Install This Operator Without Safety Edges and Photo Beams!
APPROPRIATE ENTRY/EXIT DEVICES WILL BE REQUIRED - SEE YOUR DEALER.
Przeglądanie stron 0
1 2 3 4 5 6 ... 36 37

Podsumowanie treści

Strona 1 - GP-SW050

OWNER’S MANUALGP-SW050Residential Duty Swing Gate OperatorWith Inherent UPS Battery Back-up SystemGPSW050 rev - 04/07/08Printed in China for GTO, i

Strona 2 - WARNING!

7 Technical Specications Motor•BrushlessDCmotor24VDC300watts•½Horsepower•Maximummotorcurrent20Amp•2500RPM•Openandclosetimefo

Strona 3 - Table of Contents

8 Owner’s ManualOwner’s ManualGTO/PRO GP-SW050AC Powered Swing Gate OperatorsWARNINGReducer /Operator ArmGate Bracket1/2" Washer (2)Plastic Spac

Strona 4 - Important Safety Instructions

9This unit must only be installed by an experienced technician.Preparation of the GateBefore installing the GTO swing gate operator, make sure:• the

Strona 5

10Using the Mounting TemplateThe mounting template (see insert)isdesignedtosimplifymountingtheoperator.Itprovidestheinstallerwiththepro

Strona 6

11Mounting Template (NOTTOSCALE)10”2½”3”11”6 3/8”4 5/8”Drill 3/8” x 3” deep6 places. Use 3/8”wedge type anchors.18½“ FromHinge Centerline7“ FromHing

Strona 7

12Removing the Operator HousingBeforeyoucangainaccesstotheoperatorframeanditsmountingholes,thehousingwillhavetoberemoved from the op

Strona 8 - Entrapment Protection

13RED WIRE to positive (+)JUMPER WIRE (Supplied)RED WIRE to positive (+)BLACK WIRE to negative (–)JUMPER WIRE (Supplied)negative (-) to positive (+)BL

Strona 9 - Warning Labels

14 IMPORTANT: Be sure the operator housing will not be hit by a fully open gate and that the gate column will not interfere when housing is installe

Strona 10 - Technical Specications

15 BoltsandWashersReducerArmKeyClosed GateClosingGate BracketOperator ArmReducer Arm(approx)5°-10° AngleClevis PinHairpin ClipOutput ShaftFig. 1Fig.

Strona 11 - Parts Identication

16Control Board Description1 2 3 4ONLOCKCOMCOMCOMALARMCYCLESAFETYSHADOWOPENCLOSESTOPOPENEDGECLOSEEDGESTATUSSTALL FORCE ADJUSTLIMIT ADJUSTMENTS

Strona 12 - Installing the Gate Operator

The GP-SW050 automatic gate operators are intended for use with vehicular swing gates. The operators can be used in Class I, II, III, and IV applicat

Strona 13 - Using the Mounting Template

17COMCOMCOMOPENCLOSESTOPCLOSEEDGELIMIT ADJUSTMENTSTEST SWITCHESCLOSE STOP OPENGTO Inc. Tallahassee, FLSX4000 Logic Board Rev. EMIN MAX MIN MAX O

Strona 14 - (NOTTOSCALE)

18Stall Force and Auto-Close AdjustmentsStall Force Adjustment: IMPORTANT: For safety reasons, the STALL FORCE potentiometers are set at the “10 o’c

Strona 15 - Mounting the Operator

191 2 3 4ONLOCKALARMCYCLESAFETYSHADOWOPENEDGESTATUSSTALL FORCE ADJUSTDUALLINKGTO LOOP DETECTORSLIMIT SENSORSDIAG. PORTBLDC SPEED CONTR

Strona 16

201 CYCLE:(Typicallyforusewithdoorbellbuttonorhardwiredkeypad) • Eachactivationatthisinputwillcycletheoperationasfollows: 

Strona 17 - Gate Arm Connection Overview

211 2 3 4ONLOCKCOMCOMCOMALARMCYCLESAFETYSHADOWOPENCLOSESTOPOPENEDGECLOSEEDGESTATUSSTALL FORCE ADJUSTLIMIT ADJUSTMENTSDUALLINKGTO LOOP DETE

Strona 18 - IN THIS AREA

22Output ConnectionsNote: • Maximumratingforallrelayoutputsare24Vac/dc,1Amp. • Allrelayoutputsaredrycontact(novoltage)switching.

Strona 19 - Control Board Description

23Accessory Power Supply Connection• 12Vdc@300mA(.3A)maximumpowersupplyforadditionalaccessories.• Ifyoulosepowertoyouraccessories,t

Strona 20 - Setting the Limits

24Prison Mode Operation (CLASS IV APPLICATIONS)Prison mode operation means that constant pressure at the CLOSE or the OPEN push button station in

Strona 21 - Auto-Close Adjustment:

25Reinstalling the Operator HousingChecktomakesurethesafetyedges,photoelectricbeams,warningsigns,andpedestriangate(ifnecessary)areins

Strona 22 - DIP Switch Settings

26• Thesetwo(2)terminalsprovidecommunicationconnectionsfordualgateapplicationswhereone  unit operates as a master and the other as sla

Strona 23 - Input Connections

Table of ContentsGate Operator Class Categories ...InsideCoverMetr

Strona 24 - Refer to Exit Wand manual

27Setting Dual Gate SequenceGP-SW050operatorscomefromthefactorywiththe#2DIPswitchessettoOFF.DIP Switches must be changed to accommodate

Strona 25 - Output Connections

28Safety EdgesWarning SignWarning SignSafety EdgeSafety EdgeMaster OperatorSlave OperatorUse Rigid Conduitfor inbound AC.Use Rigid Conduitfor inbound

Strona 26 - Power Supply

29MaintenanceMaintenance Schedule:•Testtheoperator,accessories,andsafetydevicesmonthly.•Servicethegateoperator,accessories,andsafety

Strona 27 - Wiring a 3-button station

30TroubleShooting GuideWARNING: ALWAYS TURN OPERATOR OFF AND DISCONNECTBATTERIES BEFORE ADJUSTING OR SERVICING IT.SYMPTOM DIAGNOSIS CHECKOne beep eve

Strona 28 - Allen Bolts

31SYMPTOM DIAGNOSIS CHECKCycle LED ON brightlyStatus Light ashesCycle terminal shorted to Com • Pushbuttonorkeyonkeypadis stuck.• Wire

Strona 29 - Dual Gate Link Connection

32SYMPTOM DIAGNOSIS CHECKClose Edge LED ONbrightly Status LightashesCloseEdgeterminalshortedtoCom• Edgesensorissensingan obstruction.

Strona 30 - Setting Dual Gate Sequence

33Warranty and Repair Service GTO AC Powered Gate Operator Limited WarrantyGTO AC powered gate operators are warranted by the manufacturer against def

Strona 31 - Slave Operator

Installation ChecklistThe installation of this operator conforms to CLASS __________.Theinstallerveriesthat(eachitemmustbechecked):____ Requi

Strona 32 - Maintenance

1Important Safety InstructionsSAFETY INSTRUCTIONS FOR THE GPSW050 SWING GATE OPERATORSIMPORTANT SAFETY INSTRUCTIONS for the System DesignerWARNING:

Strona 33 - TroubleShooting Guide

2Important Safety InstructionsIMPORTANT SAFETY INSTRUCTIONS For the InstallerWARNING–To reduce the risk of injury or death:I. Before Installation 1.

Strona 34 - GP-SW050 Visual Feedback

3Important Safety InstructionsIMPORTANT SAFETY INSTRUCTIONS Specic to Secondary Means of Protection Against EntrapmentAsspeciedbyUnderwritersLab

Strona 35 - SYMPTOM DIAGNOSIS CHECK

4Important Safety InstructionsImportant Safety Instructions fortheConsumer/EndUserWARNING: To reduce the risk of injury or death: 1. READ AND FOL

Strona 36 - Warranty and Repair Service

5Important Safety InstructionsRequired Safety Precautions for GatesSafety Edge Safety EdgeSafety EdgePhoto BeamsWarning Sign Pedestrian GateVehicle Ga

Strona 37 - Installation Checklist

6Important Safety InstructionsWarning Labels Thesewarningsignsandlabelsshouldbefoundatthelocationsspeciedbelow.Ifanyofthemaremissin

Komentarze do niniejszej Instrukcji

Brak uwag